| Plaats van herkomst: | China |
| Merknaam: | BRANDO |
| Certificering: | None |
| Modelnummer: | 4V210-06 |
| Min. bestelaantal: | 300 stuks |
|---|---|
| Prijs: | Onderhandelbaar |
| Verpakking Details: | Binnendoos, karton, pallet |
| Levertijd: | Onderhandeling |
| Betalingscondities: | T/T,Western Union,MoneyGram |
| Levering vermogen: | 100.000 stuks per maand |
| Poortgrootte: | In=Out=Exhaust=1/8" | Drukbereik: | 0,15 aan 0.8MPa (21 aan 114PSI) |
|---|---|---|---|
| Lichaamsmateriaal: | Aluminiumlegering | Ventieltype: | 5/2 Manier, Enige Solenoïde |
| Maximale drukweerstand: | 1.5MPa (215PSI) | Max. Frequentie: | 5 cyclus/Tweede |
| Spanningen: | 220V AC, 110V AC, 24V AC, 24V gelijkstroom, 12V gelijkstroom | ||
| Markeren: | Pneumatic Solenoid Valve 4V210-06,4V200 Series Solenoid Valve,Airtac 4V210-06 Solenoid Air Valve |
||
4V210-06 Airtac Type Pneumatic Solenoid Valve 4V210-06-DC24V DC24V
Pneumatic solenoid valve takes an electrical signal (ac or dc Voltage) and opens or closes the air supply going to your pneumatic actuator. Very basic solenoids consist of an electromagnetic coil, a plunger or piston, a piston return spring, and a valve body. When you apply electrical power to the coil, it attracts the piston and causes it to move inside the valve body. This, in turn, opens or closes ports inside the valve body allowing your air supply to operate the pneumatic actuator. When the electric supply is removed, the piston spring returns the piston to its original position and shuts off the air supply to the pneumatic actuator.
Data of 4V200 Series Pneumatic Solenoid Valves:
Dimension of 4V210-06 Pneumatic Solenoid Valve:
![]()
Production Video of Pneumatic Solenoid Valves:
More Pneumatic Products for you to choose:
![]()
![]()
![]()
![]()
Solenoid Operator Manifold Silencer Pneumatic Hose Fittings
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Contactpersoon: Mr. Brandon Bao
Tel.: 86-13454729544
Fax: 86-574-83879820
3“ van de het Diafragmaimpuls van dmf-z-76S BFEC de Filter van Jet Solenoid Valve For Bag
Het Type van CA25DD Goyen DD de Collector van Jet Diaphragm Valve For Dust van de Reeksimpuls
1“ het Type van SCG353A044 ASCO Diafragmaimpuls Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4“ Danfoss-Type de Klep van de Koelingssolenoïde 220VAC
1028/3 Castel Type 3/8“ de Klep van de Koelingssolenoïde HM2 220VAC 230VAC
EVRA 40 het Type van Engels-JS1025 Danfoss de Klep van de Ammoniaksolenoïde 042H1128 042H1132
C113443c113444 Diafragma voor ASCO-Impulsklep SCG353A043 SCG353A044
Diafragma voor BFEC-Impulsklep 1,5“ dmf-z-JAREN '40 dmf-zm-JAREN '40 dmf-y-JAREN '40
De Klep CA76T CA76MM van Kit For Goyen Pulse Solenoid van het K7600k7601 Diafragma