UNI-D Type SUS-10 2S040-10 3/8'' Stainless Steel Water Solenoid Valve
2S Series Solenoid Valve: 2S025-06, 2S025-08, 2S040-10, 2S160-15, 2S200-20, 2S250-25, 2S350-35, 2S400-40, 2S500-50
2W Series Solenoid Valve: 2W025-06, 2W025-08, 2W040-10, 2W160-15, 2W200-20, 2W250-25, 2W350-35, 2W400-40, 2W500-50
Port Size Range: 1/4'', 3/8'', 1/2'', 3/4'', 1'', 1 1/4'', 1 1/2'', 2''
Voltages: 12VDC, 24VDC, 110VAC, 220VAC
The electric solenoid valve is made of high quality 304 stainless steel material, with long serving life. This electric solenoid valve is Normally Closed(N/C) Type, suitable for water, air, oil, gas transfer. It is suitable for automatic cleaning of electrical equipment, solar water heater, garden spray irrigation, infrared sensor cleaning device and so on.
Technical Data of 2W & 2S Solenoid Valve:
2W Series
|
2W025-08
|
2W040-10
|
2W160-15
|
2W200-20
|
2W250-25
|
2W350-35
|
2W400-40
|
2W500-50
|
2S Series
|
2S025-08
|
2S040-10
|
2S160-15
|
2S200-20
|
2S250-25
|
2S350-35
|
2S400-40
|
2S500-50
|
Orifice Size
|
2.5
|
4
|
15
|
20
|
25
|
35
|
40
|
50
|
Port Size
|
1/4''
|
3/8''
|
1/2''
|
3/4''
|
1''
|
1-1/4''
|
1-1/2''
|
2''
|
Medium
|
Water, Air, Gas, Oil
|
|||||||
Action
|
Direct Acting
|
Semi-Direct Diaphragm Operated
|
||||||
Function
|
2 Way, Normally Closed
|
|||||||
Fluid Viscosity
|
20 CST below
|
|||||||
Pressure
Range
|
0 to 1.0 Mpa
|
|||||||
Temp. Range
|
-5 to +85℃
|
Main dimension of 2W & 2S Series Solenoid Valves:
2S Series
|
2W Series
|
A
|
B
|
C
|
D
|
E
|
2S025-06
|
2W025-06
|
64.5
|
30
|
75
|
43
|
1/8''
|
2S025-08
|
2W025-08
|
64.5
|
30
|
75
|
43
|
1/4''
|
2S040-10
|
2W040-10
|
70.6
|
32
|
82.4
|
53
|
3/8''
|
2S160-10
|
2W160-10
|
101.5
|
57
|
117
|
69
|
3/8''
|
2S160-15
|
2W160-15
|
101.5
|
57
|
117
|
69
|
1/2''
|
2S200-20
|
2W200-20
|
107
|
57
|
123.5
|
73
|
3/4''
|
2S250-25
|
2W250-25
|
111.5
|
73.5
|
134.5
|
99
|
1''
|
2S350-35
|
2W350-35
|
142
|
95
|
172
|
123
|
1-1/4''
|
2S400-40
|
2W400-40
|
142
|
95
|
172
|
123
|
1-1/2''
|
2S500-50
|
2W500-50
|
172
|
123
|
209
|
168
|
2''
|
How to choose normally open or closed solenoid valve?
In general, we select solenoid valve type according to the continuous working period. Common types include normally open, normally closed and self-retaining type. Specific rules as blows:
When the solenoid valve has prolonged on state, and the opening time is much longer than the closing time, we choose normally open solenoid valve.
When the solenoid valve has long-term off state, and the closing time is much longer than the opening time, we should choose normally closed solenoid valve.
When the solenoid valve requires same time on the opening and closing, we should choose self-retaining type solenoid valve, also called double acting type.
For some working conditions used for safety protection, such as the furnace flame detecting and other conditions, normally open solenoid valve is not applicable; we should choose long-term electricity type.
For gas leak alarm device system, we should choose normally open type gas emergency shut-off solenoid valve. After closing, the solenoid valve should be started up manually.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Contactpersoon: Brandon
Tel.: +8613454729544
3“ van de het Diafragmaimpuls van dmf-z-76S BFEC de Filter van Jet Solenoid Valve For Bag
Het Type van CA25DD Goyen DD de Collector van Jet Diaphragm Valve For Dust van de Reeksimpuls
1“ het Type van SCG353A044 ASCO Diafragmaimpuls Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4“ Danfoss-Type de Klep van de Koelingssolenoïde 220VAC
1028/3 Castel Type 3/8“ de Klep van de Koelingssolenoïde HM2 220VAC 230VAC
EVRA 40 het Type van Engels-JS1025 Danfoss de Klep van de Ammoniaksolenoïde 042H1128 042H1132
C113443c113444 Diafragma voor ASCO-Impulsklep SCG353A043 SCG353A044
Diafragma voor BFEC-Impulsklep 1,5“ dmf-z-JAREN '40 dmf-zm-JAREN '40 dmf-y-JAREN '40
De Klep CA76T CA76MM van Kit For Goyen Pulse Solenoid van het K7600k7601 Diafragma